考虑氢储能热平衡的风-氢混合系统优化调度方法

司杨1,2, 陈来军1, 麻林瑞1, 高梦宇1, 陈晓弢1, 梅生伟1,2   

  1. 1.青海省清洁能源高效利用重点实验室(青海大学启迪新能源学院),青海 西宁 810016
    2.电力系统及发电设备控制和仿真国家重点实验室(清华大学电机系), 北京 100091
  • 收稿日期:2021-06-28 出版日期:2021-11-30 发布日期:2022-01-25
  • 作者简介:司 杨(1982—),男,副教授,博士,研究方向为清洁能源综合利用。|陈来军(1985—),男,教授,博士,研究方向为电力系统稳定与控制。|麻林瑞(1989—),男,讲师,博士,研究方向为可再生能源与工程热物理。
  • 基金资助:
    * 国家自然科学基金智能电网联合基金(U1766203);青海省重点研发与转化计划项目(2021-GX-109);青海省基础研究计划项目(2021-ZJ-948Q)

Optimal Dispatching Method of Wind-Hydrogen Hybrid System Considering Heat Balance of Hydrogen Energy Storage

SI Yang1,2, CHEN Laijun1, MA Linrui1, GAO Mengyu1, CHEN Xiaotao1, MEI Shengwei1,2   

  1. 1. Qinghai Key Lab of Efficient Utilization of Clean Energy (Tus-Institute for Renewable Energy),Qinghai University,Xining 810016, China
    2. State Key Laboratory of Control and Simulation of Power System and Power Generation Equipment (Electric Machinery Department,Tsinghua University),Beijing 100091,China
  • Received:2021-06-28 Online:2021-11-30 Published:2022-01-25

摘要:

风-氢混合系统(W-HHS)参与电网调度时,氢储能系统(HESS)间歇工作的热能需求特性成为影响系统调度的关键因素。建立了具备余热利用系统的HESS模型,在HESS热量平衡和热功率平衡约束下,提出了以提高W-HHS运行收益为目标,满足混合系统输出功率跟踪电网调度曲线约束的W-HHS优化调度方法。最后,通过青海风电场数据对所提方法和模型进行了验证和分析。结果表明,HESS热平衡约束对W-HHS运行调度具有重要影响,所提方法能提高W-HHS运行的可靠性。参数分析说明,减小散热系数能够降低热平衡约束对W-HHS调度策略的影响,提高风电场并网功率。

关键词: 氢储能, 混合系统, 优化调度, 分布鲁棒, 热平衡

Abstract:

When wind-hydrogen hybrid system (W-HHS) participates in grid,the heat demand characteristics of hydrogen energy storage system (HESS) working intermittently become the key factor affecting system dispatching.A HESS model with waste heat utilization system is established.Under the heat balance constraints composed of heat power balance and thermal energy balance of HESS,an optimal dispatching method of W-HHS is proposed to improve the profit and meet the constraints of tracking grid dispatching curve.Finally,the proposed model and method are verified and analyzed through an example of Qinghai wind plant data.The results show that the heat balance constraints of the HESS have an important impact on the operation and dispatching of the W-HHS.The proposed dispatching method improves the operation reliability of the W-HHS on the premise of ensuring the heat power balance and thermal energy balance of the HESS.Parameter analysis shows that reducing the heat dissipation coefficient can decrease the impact of heat balance constraints on the dispatching strategy of W-HHS and improve the grid connected power of wind plant.

Key words: hydrogen energy storage, hybrid system, optimal dispatching, distributionally robust, heat balance