LOW VOLTAGE APPARATUS ›› 2023, Vol. 0 ›› Issue (8): 29-32.doi: 10.16628/j.cnki.2095-8188.2023.08.005

• Research & Analysis • Previous Articles     Next Articles

Analysis on Vibration Characteristic of Contactor Based on Modelica

ZHAO Yong, MA Wei, WANG Jianxiong   

  1. Guizhou Zhenhua Qunying Electric Appliance Co., Ltd., China Zhenhua Electronics Group, Guiyang 550018, China
  • Received:2023-05-06 Online:2023-08-30 Published:2023-10-19

Abstract:

To study the failure mechanism of contactors in vibration environments, taking a high-voltage DC contactor as an example, the mathematical model of its four degree of freedom vibration system is built and solved using Modelica, which is a language based on equations. By defining the acceleration amplification factor and analyzing the influence factors, it is found that the acceleration amplification factor is decreasing and the anti-vibration characteristics of the product is improving with the increase of the spacer stiffness. Finally, the measured acceleration amplification factor is obtained by testing two different material of spacers on the vibration test-bed. The measured data is consistent with the theoretical results. The conclusions are valuable for the anti-vibration design of the product.

Key words: contactor, vibration characteristic, Modelica, vibration test-bed

CLC Number: