LOW VOLTAGE APPARATUS ›› 2026, Vol. 0 ›› Issue (5): 8-16.doi: 10.16628/j.cnki.2095-8188.2026.05.002

• Research & Analysis • Previous Articles     Next Articles

Research on Improved SOGI-PLL Control Method for Single-Phase Grid-Connected Inverters

YE Ling1, CHEN Shirong2, YE Peng2, WU Ziran1,3, LIANG Bumeng2, CHEN Chong1,3   

  1. 1 Zhejiang Key Laboratory of Smart Low-Voltage Apparatus and New Energy Application, Wenzhou University, Wenzhou 325035, China
    2 Zhejiang Juchuang Smartech Co., Ltd., Wenzhou 325036, China
    3 Technology Institute of Wenzhou University in Yueqing, Yueqing 325699, China
  • Received:2026-03-03 Online:2026-05-30 Published:2026-06-09

Abstract:

With the increasing demand for renewable energy integration,the synchronization accuracy and power quality of grid-connected inverters have a significant impact on grid stability.To improve the comprehensive performance of single-phase grid-connected inverters,the control scheme of the second-order generalized integrator phase-locked loop (SOGI-PLL) is studied.An APF-SOGI-PLL structure combined with an all-pass filter (APF) and a frequency-locked loop (FLL) is proposed to improve anti-interference ability and frequency tracking performance.Proportional odd-harmonic repetitive control is adopted to enhance harmonic suppression capability.A passive damping method is used to suppress resonant peaks and improve system stability.A simulation model of a 1 kW grid-connected inverter is built in Simulink.Simulation results show that the proposed APF-SOGI-PLL can effectively suppress DC offset and achieve fast frequency synchronization under grid frequency fluctuations.The total harmonic distortion (THD) of the grid-connected current is lower than 0.70%,and the comprehensive performance is superior to that of the comparison methods.

Key words: grid-connected inverter, DC component suppression, frequency adaptation, harmonic suppression